← Test Library
Internal engineering test · Method: Internal protocol
Topper Migration Under Repeated Motion
Scheduled — no results yetCS-TST-005
- Product revision
- CS-MATTRESS-2026-08-A
Internal engineering test — not an EN, ASTM, CPSC or medical certification.
What are we testing?
Can repeated adult movement cause the full-width topper to move enough to expose an underlying mattress join or create a meaningful perimeter gap?
Why this test matters
- The topper's job is to keep the sleeper off the module joins — so migration under realistic movement is the direct engineering question.
Method basis
Co-sleeping.com internal protocol using a documented 90 kg distributed body load moved laterally through a fixed travel distance for 500 cycles, on a bed fully assembled according to normal instructions.
Planned procedure (draft protocol)
- 1Mark all four topper corners and reference points.
- 2Apply the documented 90 kg distributed load at the fixed starting position.
- 3Move the loaded form laterally through the predefined travel, at consistent speed.
- 4Record topper position at 0 / 100 / 250 / 500 cycles.
Loads / conditions
- 90 kg distributed, ±150 mm lateral travel (defined before test), 500 cycles
What will be recorded
- Longitudinal and lateral displacement at each corner
- Maximum exposed edge movement
- Whether any underlying module join becomes exposed
- Module separation underneath
- Cover/seam condition
Result
Scheduled
This test has not been run yet under the current documentation protocol. No result is published until a dated, signed internal test record exists for the stated product revision.